Solar road studs can emit light steadily throughout the night. The core principle is that they absorb solar energy during the day and store it. However, unlike conventional photovoltaic equipment, solar road studs are installed flat on the ground, and the top solar panels are easily covered by pollutants. Many users mistakenly believe that the road studs can operate automatically without maintenance, eventually resulting in reduced brightness and nighttime power failure problems.
Authoritative research data from the photovoltaic industry indicates that dust accumulation significantly reduces the efficiency of photovoltaic modules. The daily energy loss ranges from 2.8% to 50%, depending on the dust accumulation density. Data from the National Renewable Energy Laboratory (NREL) confirms that the annual dust-induced power loss varies greatly in different regions. In the United States, the loss is approximately 7%, while in the Middle East, it can reach up to 50%.
Compared to tilted roof photovoltaic systems, the ground-mounted, nearly horizontal solar road studs have harsher conditions. They are constantly exposed to tire dust and road mud and water, and the dust accumulation problem is more prominent. This article will thoroughly analyze how dust accumulation affects the operation of the road studs and share non-destructive, standardized panel cleaning and maintenance methods.
In the photovoltaic operation and maintenance industry, the power loss caused by dust shading is collectively referred to as Soiling (dust contamination), which is the most common hidden fault of outdoor photovoltaic equipment. This loss does not directly damage the hardware of the equipment, but it will continuously erode the charging capacity of the road studs.
Multiple measured data have confirmed the severity of the dust problem: in a regular dust environment, the daily power loss of solar photovoltaic equipment is stable at 2.8% to 50%; NREL’s long-term monitoring data shows that the annual dust loss varies from 7% to 50%. Special studies on pavement photovoltaic equipment also indicate that for road studs that have not been cleaned for a long time, the power efficiency drop within one month can be as high as 50%, directly leading to insufficient nighttime power supply.
Many users believe that a small amount of dust and stains have little impact. In fact, this is a huge misconception. The internal battery cells of solar road studs operate in a series mode, and this structural characteristic causes a disproportionate power loss due to local shading.
In simple terms, a series battery pack is like a series circuit, and when a single battery cell is shaded and its power generation is limited, it directly lowers the total output power of the entire module. Even if only a thin layer of dust or a spot of stain appears on the panel, it will not only cause local loss but also significantly reduce the power generation and energy storage performance of the entire road stud.
The solar panel is the only energy collection component of the road stud and is the part of the entire device with the highest exposure and the lowest fault tolerance. The road stud is installed flatly, and the top panel is completely facing upwards, without any shading protection.
Compared to large roof photovoltaic panels, the surface area of the road stud panels is small, and the effective light-receiving area is already limited. A small amount of dust can cover most of the light-receiving area, and there is no extra light collection capacity to offset the loss. Therefore, the impact of dust on the road stud is much greater than that of ordinary photovoltaic panels.
The rain self-cleaning ability of photovoltaic equipment is mainly determined by the installation inclination angle. The larger the inclination angle, the better the combined effect of rain flushing, gravity sliding, and wind blowing, and the less likely the pollutants will adhere and remain.
Outdoor real measurement data from Malaysia clearly confirm this rule: photovoltaic components with installation inclination angles of 14°, 24°, and 34° have annual efficiency losses of 3.1%, 2.9%, and 2.5% respectively. Industry operation practice also clearly indicates that photovoltaic equipment requires an inclination angle of at least 5° to achieve self-cleaning through natural forces, such as debris falling and foundation self-cleaning.
The inclination angle for conventional rooftop photovoltaic installations is generally between 15° and 35°. They can be cleaned by rain, wind, and gravity on a daily basis. However, solar road studs are installed at nearly 0° to fit the road surface and ensure driving safety.
Under this installation structure, rainwater cannot form rapid-flowing water currents. It not only cannot remove dust but also traps mud, dust, and sediment on the panel surface. After water evaporation, mud and sand will firmly adhere to the panel, forming a stubborn dust layer that continuously blocks light.
The accumulation of dust in the natural environment is already difficult to remove on its own. Roadways continuously add pollution to the road studs. During vehicle travel, dust from the road surface is continuously stirred up, and heavy trucks and rainy driving will constantly splash mud, sand, and gravel.
These pollutants continuously adhere to the surface of the road stud panels, creating a state of “old dust not cleared, new dust accumulates again”. In conclusion, the operation experience of rooftop photovoltaic systems for “self-cleaning by rainwater” is completely not applicable to solar road studs. Simply relying on natural rainfall cannot maintain panel cleanliness and power generation efficiency.
In different road sections and under different climatic conditions, the types of pollutants on the road stud panels vary greatly, and the corresponding fault manifestations and handling methods are also completely different. The following comparison table clearly summarizes the key information of the three core pollutants:
| Pollution Type | Common Scenarios | Core Characteristics | Device Impact | Basic Response Methods |
| Dry Sand and Dust | Desert areas, dry sections in northern regions, and windy, dust-prone areas | Dust forms a uniform layer over the panel without clumping or strong adhesion. Accumulation gradually increases over time. | Continuous and gradual decline in power generation efficiency. No obvious short-term faults, but battery life may gradually decrease over the long term. | Conduct regular inspections and dry dust removal. Lightly wipe with clean water when necessary and regularly remove loose dust. |
| Mud Splashing | Rainy sections, rural dirt roads, construction areas, and muddy urban-rural roads | Mud covers the panel and forms a hard, opaque layer after drying, significantly reducing light transmission. | Sharp reduction in light transmission and power generation performance, potentially causing insufficient brightness at night and premature lighting-off. | Gently clean the panel after the mud softens. Do not scrape or chip the mud with hard tools. Perform thorough cleaning after rainfall. |
| Biological Film Pollution | Tropical and subtropical humid regions, long-term damp and shaded areas, and roads near water | Algae, moss, and mold form sticky biological films on the panel that are difficult to remove naturally. | Continuous light obstruction; may also affect the panel’s UV-resistant coating, accelerating housing aging, yellowing, and cracking. | Use neutral cleaning agents for cleaning. Disinfect regularly to inhibit biological growth and prevent long-term dirt accumulation in humid environments. |
The structure of solar road studs is precise and has high sealing requirements. The core principle of cleaning is: only clean the surface, do not disassemble the equipment, and do not damage the coating and sealing structure.
Recommended standardized cleaning solution: use low-pressure clean water for rinsing, combined with soft brushes and ultra-fine soft cloths for gentle wiping; if there are stubborn stains or biological films, you can combine with neutral eco-friendly cleaning agents. After cleaning, wipe away the remaining residue with clean water and let it air dry naturally. No disassembly of the road studs is required, avoiding damage to the factory-sealed structure.
Many operational failures are not caused by natural aging of the equipment, but by improper cleaning operations. The following three operations are clearly prohibited in the industry:
High-pressure water flow will break through the sealing rubber ring of the road studs and forcibly enter the equipment interior, causing circuit short-circuit, battery moisture damage, which is a consensus taboo operation in the photovoltaic operation industry.
These tools and materials will directly scratch the panel’s UV-resistant protective coating, losing the coating protection, the panel will quickly yellow, fog, and age, permanently reducing light transmittance.
Corrosive solvents can erode the PC casing and sealing strips, accelerating the aging of the equipment and causing the sealing performance to fail. In the later stage, water infiltration faults are highly likely to occur.
It is not recommended to directly spray cold water onto the road stud panels during the summer noon or during periods of intense heat exposure. When the equipment is in a high-temperature state and suddenly encounters cold, thermal stress will be generated. Repeated operations over time may lead to panel cracking and sealing component deformation. It is recommended to carry out cleaning operations in the early morning or evening when the temperature is low.
Compared to rooftop photovoltaic panels, the operational tolerance of solar road stud panels is extremely low. The road stud panels are small in size and the internal sealing space is compact, making it impossible to install additional protective accessories.
If the cleaning operation is improper and causes water infiltration, coating scratches, or sealing damage, it is unlikely to be remedied through later repairs and is likely to be directly scrapped and replaced. Therefore, road stud panel cleaning must strictly follow the no-damage standard and cannot adopt the loose operation mode of large-scale photovoltaic panels.
There is no fixed and unified cycle for cleaning. The core is to adjust flexibly based on the speed of road surface pollution and climate conditions to meet the operational needs of different scenarios:
Dry sandy areas: Dust accumulates continuously, and it is recommended to clean once every 1-2 months;
Muddy sections during rainy seasons, clean as needed after each concentrated rainfall;
Humid tropical areas, biological films are prone to grow, and it is recommended to clean to inhibit bacteria once a month.
The optimal operation plan is to combine panel cleaning with regular equipment inspections. During the inspection, the maintenance personnel check the brightness, endurance, and fixation status of the road stud panels, and simultaneously complete surface dust removal and stain cleaning. One operation can complete both tasks, significantly saving labor and travel costs.
The replacement cost of a single solar road stud panel is much higher than the daily cleaning cost. The entire non-destructive cleaning process has almost no material cost, and the labor time is very little. The cleaning cost of a single panel can be controlled within $0.5.
Compared to the high expenditure of equipment failure replacement and batch maintenance, regular cleaning is the most cost-effective and effective maintenance action in the entire road stud panel operation system, which can effectively extend the equipment’s service life by 3-5 years.
No, that’s not possible. The nearly horizontal installation angle of the road studs makes it impossible for rainwater to wash them clean. Instead, the rainwater will remain on the panel surface, dry and form a layer of mud and dirt, which will actually increase pollution and cannot replace manual cleaning.
Absolutely not. The high-pressure water gun will damage the equipment’s sealing structure, allowing water vapor to seep inside, causing short circuits, battery damage and other faults. This is a uniformly prohibited cleaning method in the industry.
There is no fixed standard. They should be cleaned as needed according to the environment: in dry sandy areas, it should be done once every 1-2 months; in muddy sections during rainy seasons, they should be cleaned immediately after rain; in humid tropical areas, they should be cleaned once a month. This can be combined with regular inspections to complete at the same time.
Most likely. Dust, mud crusts, and biofilms blocking the light will directly reduce the daytime charging efficiency, leading to insufficient energy storage and ultimately resulting in a decrease in night brightness and a shorter lighting duration. This is the primary cause of the road studs becoming dim.
Dust accumulation is the most underestimated latent failure factor in the operation and maintenance of solar road studs. It does not directly damage the hardware of the equipment, but it will quietly block the energy collection, causing the road studs to remain “powerless and short of electricity”. Daily cleaning is not merely an appearance maintenance; it is the core means to ensure the stable lighting of the studs at night and extend the equipment’s lifespan. It is also the lowest-cost and most intuitive maintenance method.